Metrohm IC Net 2.0 Bedienungsanleitung Seite 111

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 196
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 110
7.2 Passport
IC Net 2.0
103
7.2.4 Eluent
Tab Eluent of passport with eluent information.
Eluent A Description of eluent composition (max.
256 characters).
Eluent B Description of eluent composition (max.
256 characters).
Eluent C Description of eluent composition (max.
256 characters).
Flow Flow rate of the high-pressure pump in
mL/min or µL/min. The flow rate is used to
recalculate the time axis into volumetric
units. The system startup value for the flow
rate is entered automatically into this field
at the start of a determination with Start with
inject.
Pressure Pressure in Mpa, psi, bar, or atm. The
measured value for the pressure is entered
automatically into this field at the start of a
determination with Start with inject.
Temp. Temperature in °C. Here you can enter the
temperature of the column’s thermostat or
the ambient temperature.
Seitenansicht 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 195 196

Kommentare zu diesen Handbüchern

Keine Kommentare